| Physical |
| Height |
3.5
inches |
| Width |
16.5
inches (excluding mounting ears) |
| Depth |
9.5
inches |
| Weight |
10
pounds |
| Electrical |
| Input Voltage |
| CIUS-L |
-48
VDC nominal (-42 to -60 VDC) |
| CIUS-H |
125
VDC nominal (105 to 150 VDC) |
| 120
VAC nominal (90 to 135 VAC) |
| Maximum Current Draw |
1100
mA maximum (fuse at 2 amps) |
| Transmit Power |
3
watts maximum |
| Environmental |
| Operating Temperature |
-20°C to + 60°C |
| Humidity |
to
95% non-condensing |
| Reliability |
| Mean Time Between Failures (MTBF) |
5 years |
| Regulatory Compliance |
| FCC Part 15 Class A |
Approved |
| FCC Part 68 |
1LZUSA-23190-MO-T |
| REN |
0.1B |
| Fire Resistance |
| Composite oxygen index |
28%
or greater |
| Complies with US 94 V-1 |
|
| Surge Compliance |
IEEE
C37.90.1-1989 SWC on power, alarm leads |
| Electrostatic Discharge |
| The
CIUS will not be damaged and will continue to operate
when subjected to discharges at Severity Level 2 (4KV)
and Severity Level 4 (15KV) as defined by IEC Publication
801-2, Second Edition 1991. |
| Warranty
Info |
| The Cellular Interface Unit is warranted for a period
of 1 year. |